The unit may be screwed or bolted down using the supplied white, plastic washers, if desired. A mounting kit is supplied with the W50F that includes rubber mounts and steel inserts. Consideration should be given for access to the hose and refrigerant line connections. Chapter 3 W50F - Water cooled with pump This unit must be mounted on a horizontal surface in an area where it will not be susceptible to physical or water damage, but accessible for service. Poor system performance will also result from air being drawn in from a heated space, i.e., an engine room. Re-circulating the heated air back into the condenser in a sealed or poorly ventilated cabinet will result in poor system performance. The temperature of the air entering the condenser determines the efficiency of the system. There should be adequate ventilation to allow cool air to enter the condenser, but not so that the heated expelled air can be drawn back in. Reversing the fan leads does not make the fan run in reverse and the incorrect polarity will result in the fan not operating. If air is required to be drawn into the unit from another area, the fan may be reversed by removing the housing and re-mounting the fan in the opposite orientation. A duct kit is available for the Capri 50-SSC. They require good ventilation, preferably expelling the heated air to another location by attaching a flexible duct of not more than 6' in length to the duct ring on the unit. Veco NA, LLC P O Box 3518 Annapolis MD Rev 13 12/2006 Chapter 1 Frigoboat systems A Frigoboat system consists of the following components: (1) A compressor / condensing unit that is either: Air cooled - Paris 35F or Capri 50-SSC Water cooled - W50F (with pump) Keel cooled - K50-SSC (with keel cooler) (2) An electronic controller connected to and installed on the compressor (3) Either a mechanical thermostat for refrigerator, freezer or holding plate, or a Carel digital thermostat/thermometer (4) A Smart Speed Control (SSC), standard on Capri 50-SSC and K50-SSC systemsĢ (5) An aluminum or stainless steel evaporator plate or holding plate (6) A water pump, for W50F only (7) A keel cooler, standard on K50-SSC, optional with Capri 50-SSC Chapter 2 Paris 35F and Capri 50-SSC Air cooled These units are designed to be mounted on a horizontal surface in areas where they will not be susceptible to physical or water damage, but accessible for service. 1 Frigoboat Marine Refrigeration Systems Installation & Instruction Manual For Models: Paris 35F, Capri 50-SSC, K50-SSC, W50F (Also applicable to any Frigoboat system using Danfoss BD 35 & 50 compressors) It is important to read this manual thoroughly before installing a Frigoboat system.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
December 2022
Categories |